Standard Proctor compaction test of soil (light compaction) (As per IS-2720-Part-VII-1980)
Objective Determination of water content and dry density relation of soil using light compaction. Apparatus • Cylindrical mould of 100mm diameter & accessories [volume = 1000 c.c.] • Rammer [2.6 kg] • Balance [(a) 10kg capacity & 1g accuracy (b) 200gm capacity & 0.01gm accuracy for moisture content calculation] • Sieves [19mm & 4.75mm IS …